United Faith Sdn Bhd (HQ)
6 (Ground Floor), Jalan BPU 6, Bandar Puchong Utama, 47100 Puchong, Selangor, Malaysia.
+6012-2631315
+6012-5992610

SG Branch :
United Faith Pte Ltd

7030, Ang Mo Kio Ave 5, #01-23, Northstar@AMK, Singapore 569880.
+65-9106 6813

KL Branch :
8G, Jalan Pandan 2/3, Pandan Jaya, 55100 Kuala Lumpur, Malaysia.
+6012-491 2610

PJ Branch :
13, Jalan 21/37, SS 2, 47300 Petaling Jaya, Selangor, Malaysia.
+6012-599 2610

AXIS™ Dual-Duct VAV Terminal 35L 50 to 7,100 Nominal Cfm

Previous 11 / 12 Next

AXIS™ Dual-Duct VAV Terminal 35L 50 to 7,100 Nominal Cfm Carrier Air Terminals HVAC


The 35L units offer a compact design with diverse control packages. The 35L dual-duct terminals are designed to maintain optimum temperatures in the conditioned zone by varying the air volume supplied by hot and cold supply ducts while providing the proper discharge air temperature

carrier-AHRI-880-VAV-Air-Terminal

 

Performance Features

  • Airflow capacities from 45 to 3700 cfm
  • Round inlet sizes from 4 in. through 16 in. diameter
  • Rectangular inlet on size 22
  • 22 gauge, galvanized steel casing construction
  • Converts high-pressure mechanical constant volume systems to low-pressure variable volume systems
  • Linear, multiple-point, averaging velocity sensor with an amplified signal
  • Damper blade has a flexible gasket for tight airflow shutoff
  • Damper blade operates over a full 90°
  • All damper assemblies utilize a solid ½ in. shaft that rotates in self-lubricating Delrin® bearings
  • Pressure independent or dependent controls, including Carrier i-Vu Open (BACnet), Carrier Comfort Network® (CCN), analog, or pneumatic controls

Reliability Features

  • Casings meet UL-181 and NFPA-90A requirements

Maintenance Features

  • NEMA 2 steel control enclosure for electric or electronic components
  • Label information adhered to each unit includes model, size, airflow (cfm), balancing chart, and tagging data

Installation Features

  • Factory-installed controls
  • All round collars accommodate standard spiral and flex duct sizes
  • Balancing taps provided for easy airflow verification

Factory-Installed Options

  • Control options:
    • Analog electronic controls
    • Carrier i-Vu Open VAV or VVT controls
    • Carrier Comfort Network (CCN) VAV or VVT controls
    • Pneumatic controls
  • No controls or field-supplied DDC (direct digital controls) third party controls for factory mounting
  • Left-hand or right-hand control enclosure
  • 20 gauge, galvanized steel casing
  • 304 stainless steel casing

Field-Installed Accessories

  • Remote wall sensor
  • Supply-air temperature sensor