AquaEdge® High-Efficiency Semi-Hermetic Centrifugal Chiller 19XR

Previous 7 / 7 Next

AquaEdge® High-Efficiency Semi-Hermetic Centrifugal Chiller 19XR Carrier Water Cooled Chiller


Single-Stage (200 to 1,600 Tons)

--Constant Speed
--Variable-Speed (19XRV)

Two-Stage (600 to 3,400 Tons)

--Constant Speed
--Variable-Speed (19XRV)

The AquaEdge® 19XR/XRV centrifugal chillers achieve energy efficiency levels using proven technology designed specifically for chlorine-free refrigerant. This combination ensures the most cost-effective, reliable solution for today's comfort cooling and process cooling applications.

Carrier's AquaEdge® chillers offer the best value in high-efficiency, chlorine-free centrifugal HVAC chillers.

Water-cooled chillers within the scope of the AHRI WCCL certification program are certified in accordance with the AHRI Water-Cooled Water-Chilling and Heat Pump Water-Heating Packages Certification Program, which is based on AHRI Standard 550/590 (I-P) and AHRI Standard 551/591 (SI). Certified units may be found in the AHRI Directory at www.ahridirectory.org.


carrier-AHRI-550-590-551-591_WCCL
carrier-seismic-compliant
carrier-iso-9001
carrier-intertek-ETL-listed-C-US
carrier-c-ul-us

 

Performance Features

  • IPLV to 0.31 (19XRV)
  • Chlorine-free HFC-134a refrigerant
  • Semi-hermetic compressor motor
  • Low energy consumption during part load and full load operation
  • Aerodynamically contoured impeller
  • Multilingual display
  • Compatible with Carrier Comfort Network® (CCN) communication link
  • Economized two stage compressor 19XR two-stage units)

Reliability Features

  • ASME constructed heat exchangers
  • Single-stage 200-1600 tons (703 to 5627 kW) or two-stage 600-3400 tons (2110 to 11957 kW) positive pressure design
  • Low voltage control circuits
  • Lowest industry refrigerant leakage rate at less than 0.1% per year
  • Semi-hermetically sealed compressor, motor, and transmission
  • Automated controls may be tested before start-up
  • Refrigerant-cooled, unit-mounted variable frequency drive (19XRV)

Maintenance Features

  • Password protected extensive service menu with built-in diagnostic capabilities, troubleshooting, and corrective action recommendations for preset alarms
  • Alarm and alert files maintain the last 25 time and date stamped messages in memory
  • Configuration data backup with non-volatile memory
  • Thermistor-type temperature sensor with quick connects in each water nozzle
  • Refrigerant isolation valves for in-chiller refrigerant storage (factory-installed option)
  • Unit-mounted pumpout unit for storing refrigerant inside the chiller during servicing (factory-installed option)
  • Service contract available

Installation Features

  • Low voltage control circuits
  • Refrigerant cooled unit mounted VFD
  • Less than 0.1% refrigerant leakage rate per year - lowest in the industry
  • Semi-hermetically sealed compressor, motor, and transmission 
  • Automated controls test on start-up

Factory-Installed Options

  • Enhanced tubing, .028 or .035 in. (0.711 or 0.889 mm):
    • Internally/externally enhanced copper tubing - evaporator/condenser
    • Internally/externally enhanced cupronickel tubing - condenser
    • Smooth bore/externally enhanced copper tubing - evaporator/condenser
    • Smooth bore/externally enhanced cupronickel tubing - condenser
  • Titanium condenser tubes, .025 or .028 in. (0.635 or 0.711 mm):
    • Internally enhanced tubes
  • Marine waterboxes
    • 150 psig (1034 kPa) waterbox
    • 300 psig (2068 kPa) waterbox, ASME certified
  • Marine bolt-on waterboxes for condenser, 150 psig (1034 kPa) with titanium clad tubesheets (available on condenser frame sizes 2 to 8 and A to D)
  • Nozzle-in-head waterbox, 300 psig (2068 kPa)
  • Flanged evaporator and/or condenser waterbox nozzles
  • Waterbox hinges
  • Unit-mounted, low-voltage wye-delta or solid-state starters (Heat exchanger frames 1-7 only)
  • One, 2, or 3 pass evaporator or condenser waterside construction
  • Zinc anodes
  • BACnet® Communications
  • Refrigerant isolation valves
  • Shipped factory charged with refrigerant
  • Unit-mounted pumpout unit
  • Hot gas bypass
  • Unit-mounted refrigerant-cooled variable frequency drive
  • Thermal insulation (except waterbox covers)
  • Customer factory performance testing
  • Export crating
  • Discharge line sound reduction kit
  • Seismic Kit
  • Extended Warranty (North America only)
  • Service Contract

Field-Installed Accessories

  • BACnet® Carrier Translator
  • LonWorks® Carrier translator
  • Sensor package
  • Separate storage tank and pumpout unit
  • Stand-alone pumpout unit
  • Soleplate package
  • Spring isolator kit
  • Acoustical sound insulation kit
  • Freestanding Low Voltage Wye-Delta & Solid Starters
  • Freestanding Low Voltage Variable Frequency Drives
  • Freestanding Medium Voltage Variable Frequency Drives
Heat Exchanger Size† Length with
Nozzle-in-Head Waterbox
Width Height **
2-Pass* 1 or 3-Pass
ft-in. mm ft-in. mm ft-in. mm ft-in. mm
10 to 12 11-4 3454 11-11 3632 5-2 7/8 1597 6-1 1/4 1861
15 to 17 13-7 1/2 4153 14-2 1/2 4331 5-2 7/8 1597 6-1 1/4 1861
20 to 22 11-4 3/4 3473 11-11 3/4 3651 5-6 7/8 1688 6-3 1/4 1911
30 to 32 13-8 1/4 4172 14-3 1/4 4350 5-6 7/16 1688 6-3 1/4 1911
35 to 37 15-4 3/4 4693 15-11 3/4 4870 5-6 7/16 1688 6-3 1/4 1911
40 to 42 14-3 1/8 4347 14-9 4496 6-3 1/8 1908 7-0 3/4 2153
45 to 47 15-8 5/8 4867 16-5 1/2 5017 6-3 1/8 1908 7-0 3/4 2153
50 to 54, 5K to 5R 14-4 1/2 4382 14-10 4521 6-6 1/2 1994 7-1 2159
5A to 5C 14-4 1/2 4382 14-10 4521 6-6 1/2 1994 7-1 2159
55 to 59, 5T to 5Z 16-1 4902 16-6 1/2 5042 6-6 1/2 1994 7-1 2159
5F to 5H 16-1 4902 16-6 1/2 5042 6-6 1/2 1994 7-1 2159
60 to 64, 6K to 6R 14-5 1/4 4401 14-11 4547 6-11 5/8 2124 7-4 7/8 2257
65 to 69, 6T to 6Z 16-1 3/4 4921 16-7 1/2 5067 6-11 5/8 2124 7-4 7/8 2257
70 to 74, 7K to 7R 16-6 1/8 5032 17-0 1/2 5194 8-1 1/4 2470 9-9 1/2 2985
75 to 79, 7T to 7Z 18-6 1/8 5642 19-0 1/2 5804 8-1 1/4 2470 9-9 1/2 2985
80 to 84, 8K to 8R 16-9 1/8 5109 17-3 1/2 5271 8-10 3/4 2711 9-11 1/4 3029
85 to 89, 8T to 8Z 18-9 1/8 5718 19-3 1/2 5880 8-10 3/4 2711 9-11 1/4 3029

*Assumes all customer connections are on the same end of the chiller.

**Height is for chiller without unit-mounted starter.

†Heat exchangers are rated for typical applications at AHRI Conditions (44°F leaving chilled water and 54 F entering in the evaporator, and 85°';F entering condenser water with 94.3 leaving condenser water in the condenser).

19XR Dimensions - Two-Stage Compressor Frame Sizes 6 & 7 (Dished Head Waterbox)

Cooler Heat Exchanger Size Condenser Heat Exchanger Size A (Length, Dished Head Waterbox) 19XR B Width 19XR C Height
1-Pass 2-Pass 3-Pass
ft-in. mm ft-in. mm ft-in. mm ft-in. mm
A4* A4* 17-8 5385  17-6.75 5353 17-6.75 5353 10-3.13 3127 See Note 6
A6* A6* 19-8 5994 19-6.75 5962 19-6.75 5962 10-3.13 3127
A4* B4* 17-8  5385 17-7.38 5369 17-7.38 5369 10-8.5 3264
A6* B6* 19-8 5994 19-7.38 5978 19-7.38 5978 10-8.5 3264
B6* C6* 20-0 6096 19-11.18 6074 19-9  6120 12-0.63  3674
B8* C8* 22-0 6096 21-1.18 6684 21-9 6629 12-5.5 3797
C6* C6* 20-4.25  6204 19-11.18  6074 19-11.75 6090  12-5.5  3797
C6* D6* 20-4.25  6204 20-0  6096 20-0.5  6109 13-2  4013
C8* D8* 20 6096 21-11.125  6684 21-9  6629 13-2  4013

*Assumes both cooler and condenser nozzles on same end of chiller.
Note 6. 19XR heights can vary depending on the configuration. Check 19XR certified drawings for height information.