- Ducting, Diffuser and Accessories
- Packaged Outdoor
- Split Systems and Condensers
- Actuator
- Air Compressor Parts, Components and Accessories
- Air Cond Bracket
- Air Conditioner Sensor
- Air Conditioning Control System
- Air Cooled Chiller
- Air Cooler
- Air Filters
- Air Handlers
- Air Handling System
- Air Swing Motor
- Air Swing Motor (Small)
- Air Terminals HVAC
- Air-Cond and Refrigeration Tooling
- Air-Conditioner Unit
- Anti Clog
- Automatic Drain Valve
- Belting
- Brazing Equipment & Accessories
- Carrier Parts
- Chemicals
- Chilled and Induction Beams
- Chiller Components
- Chiller Parts
- Actuators
- Bearings and Bushing
- Compressors
- Contactors
- Electronic Components
- Fans and Fan Blower Parts
- Filters and Filter Parts
- Gaskets
- Miscellaneous Electrical Parts
- Miscellaneous Fasteners and Fittings
- Miscellaneous Valves
- Motors
- O - Rings
- Oil and Fluids
- Preventive Maintenance Kits
- Pump
- Relays
- Relief Valves
- Repair Parts Kits
- Solenoid Valves
- Switches
- Thermal Expansion Valves
- Transducers
- View All
- Cleaning Equipment & Tools
- Cold Room Parts and Accesories
- Commercial Chiller Components
- Component
- Compressor
- Compressor Accessories
- Condensate Drainage Pump
- Condensing Unit
- Cooling Coil
- Cooling Tower Spare Part
- Copper and Fittings
- Copper Piping Leak Test
- Coupling
- Daikin /Acson / York Spare Parts
- Electrical
- Electronic Air Cleaner
- FAN BLADE / FAN PROPELLER
- Fan Coils
- Fan Motor
- Fan Set
- Filter Aircond
- Fire Duct Systems
- FRIDGE & REFRIGERATOR PARTS
- Hardware Items and Tools
- Induction Units
- Innerco Piercing Valve
- Insulation
- Lubricant Oil and Equipment
- Measuring Instrument
- Packaged Indoor
- Panasonic Compressor
- PCB Board
- Pressure Test Equipment and Accessories
- Refrigerant
- Sensors
- Silicone Sealant
- Spray Pump
- Temperature / Humidity Display & Controller
- Underfloor Air Distribution
- Unit Ventilators
- Vacuum Pump
- Valve (Water/Steam Application)
- Water Cooled Chiller
- York Chiller Parts
- Others
- Others
United Faith Sdn Bhd (HQ)
6 (Ground Floor), Jalan BPU 6, Bandar Puchong Utama, 47100 Puchong, Selangor, Malaysia.
+6012-5992610
SG Branch :
United Faith Pte Ltd
7030, Ang Mo Kio Ave 5, #01-23, Northstar@AMK, Singapore 569880.
+65-9106 6813
KL Branch :
8G, Jalan Pandan 2/3, Pandan Jaya, 55100 Kuala Lumpur, Malaysia.
+6012-491 2610
PJ Branch :
13, Jalan 21/37, SS 2, 47300 Petaling Jaya, Selangor, Malaysia.
+6012-599 2610
AquaEdge® High-Efficiency Variable-Speed Screw Chiller 23XRV
Previous | 6 / 7 | Next |
- Carrier Water Cooled Chiller Malaysia
- Commercial Water Cooled Chiller Malaysia
- Water Cooled Chiller Malaysia
- Carrier High-Efficiency Variable-Speed Screw Chiller 23XRV Malaysia
- High-Efficiency Variable-Speed Screw Chiller 23XRV Malaysia
175 to 550 Nominal Tons (615 to 1,934 kW)
The 23XRV chiller is the world’s first integrated variable-speed, water cooled, screw chiller. The 23XRV incorporates significant breakthroughs in water-cooled chiller technology to provide excellent reliability and achieve superior efficiency at true operating conditions without compromising the environment. Quality design and construction make the AquaEdge® 23XRV chillers the best choice for modern, efficient chilled water plants.
Carrier's AquaEdge® chillers offer the best value in high-efficiency chlorine-free variable-speed screw HVAC chillers.
Water-cooled chillers within the scope of the AHRI WCCL certification program are certified in accordance with the AHRI Water-Cooled Water-Chilling and Heat Pump Water-Heating Packages Certification Program, which is based on AHRI Standard 550/590 (I-P) and AHRI Standard 551/591 (SI). Certified units may be found in the AHRI Directory at www.ahridirectory.org.
Performance Features
- IPLV to 0.299
- Chlorine-free HFC-134a refrigerant
- Full Load kW/Ton to 0.53
- Tri-rotor, positive displacement screw compressor
- Hermetic compressor motor
- Refrigerant-cooled, unit-mounted variable frequency drive
- Low inrush current
- Operation of up to 0.99 power factor
- Flooded shell-and-tube cooler
- Float valve
- Superior oil management/cold condenser water operation
- Internally and externally enhanced 0.025 in. (0.635 mm) copper tubing
- 150 psig (1034 kPa) rated cooler and condenser
- LCD control display
- Microprocessor-based Product Integrated Control (PIC) III
- Multilingual display
- Demand limiting capability with Carrier Comfort Network® (CCN) communication link
Reliability Features
- ASME constructed heat exchangers
- PED/CE construction option
- Low voltage control circuits
- Lowest industry refrigerant leakage rate at less than 0.1%
- Hermetically sealed compressor motor
- Automated controls may be tested before start-up
- 65K AIC circuit breaker
Maintenance Features
- Password protected extensive service menu with built-in diagnostic capabilities, troubleshooting, and corrective action recommendations for preset alarms
- Alarm and alert files maintain the last 25 time and date stamped messages in memory
- Configuration data backup with non-volatile memory
- Refrigerant filter isolation valves
- Thermistor type temperature sensor with quick connects in each water nozzle
- Service contract available
Installation Features
- Modular construction
- Single point electrical connection
- Can be dismantled and reassembled
- Unit-mounted VFD with single point connection
- Small footprint
Factory-Installed Options
-
Enhanced tubing, .028 or .035 in. (0.711 or 0.889 mm):
- Internally/externally enhanced copper tubing - cooler/condenser
- Internally/externally enhanced cupronickel tubing - condenser
- Smooth bore/externally enhanced copper tubing - cooler/condenser
- Smooth bore/externally enhanced cupronickel tubing - condenser
-
Wall tubes, titanium, condenser, .025 or .028 in. (0.635 or 0.711 mm):
- Internally enhanced tubes
- Smooth bore tubes
-
Marine waterboxes (available for heat exchanger frames 3-5 only):
- 150 psig (1034 kPa) waterbox
- 300 psig (2068 kPa) waterbox
- Nozzle-in-head waterbox, 300 psig (2068 kPa)
- Hinged waterboxes
- Flanged cooler and/or condenser waterbox nozzles
- One, 2, or 3 pass cooler or condenser waterside construction
- Zinc anodes
- 100K AIC high interrupt circuit breaker with shunt trip
- Analog voltmeter and ammeter with 3-phase selector switch
- DataLINK™ or DataPort™ communication device
- Shipped factory charged with refrigerant
- Hot gas bypass
- Full cold surface thermal insulation (except waterbox covers)
- Customer factory performance testing
- Export crating
Field-Installed Accessories
- BACnet™ Carrier translator
- DataLINK™ or DataPort™ communication device
- LonWorks® Carrier translator
- Sensor package
- Separate storage tank and pumpout unit
- Stand-alone pumpout unit
- Soleplate package
- Spring isolator kit
- Refrigerant isolation valves for in-chiller refrigerant storage
- Unit-mounted pumpout unit for storing refrigerant inside the chiller during servicing
- Acoustical sound insulation kit
- Shipped fully charged
ominal Capacity (Tons)* | Heat Exchanger Size | Length with Nozzle-in-Head Waterbox | Width | Height | |||||
---|---|---|---|---|---|---|---|---|---|
2-Pass** | 1 or 3-Pass | ||||||||
ft-in | mm | ft-in | mm | ft-in | mm | ft-in | mm | ||
250-550 | 30 to 32 | 13-8¼ | 4172 | 14-3¼ | 4350 |
See Unit Certified Drawings |
See Unit Certified Drawings |
||
35 to 37 | 15-4¾ | 4693 | 15-11¾ | 4870 | |||||
40 to 42 | 14-3 1⁄8 | 4347 | 14-9 | 4496 | |||||
45 to 47 | 15-11 5⁄8 | 4867 | 16-5½ | 5017 | |||||
50 to 52 | 14-4½ | 4382 | 14-10 | 4521 | |||||
55 to 57 | 16-1 | 4902 | 16-6½ | 5042 |
*For job specific dimensions and weight information, please contact your Carrier Sales Representative.
**Assumes all customer connections are on the same end of the chiller.