- Ducting, Diffuser and Accessories
- Packaged Outdoor
- Split Systems and Condensers
- Actuator
- Air Compressor Parts, Components and Accessories
- Air Cond Bracket
- Air Conditioner Sensor
- Air Conditioning Control System
- Air Cooled Chiller
- Air Cooler
- Air Filters
- Air Handlers
- Air Handling System
- Air Swing Motor
- Air Swing Motor (Small)
- Air Terminals HVAC
- Air-Cond and Refrigeration Tooling
- Air-Conditioner Unit
- Anti Clog
- Automatic Drain Valve
- Belting
- Brazing Equipment & Accessories
- Carrier Parts
- Chemicals
- Chilled and Induction Beams
- Chiller Components
- Chiller Parts
- Actuators
- Bearings and Bushing
- Compressors
- Contactors
- Electronic Components
- Fans and Fan Blower Parts
- Filters and Filter Parts
- Gaskets
- Miscellaneous Electrical Parts
- Miscellaneous Fasteners and Fittings
- Miscellaneous Valves
- Motors
- O - Rings
- Oil and Fluids
- Preventive Maintenance Kits
- Pump
- Relays
- Relief Valves
- Repair Parts Kits
- Solenoid Valves
- Switches
- Thermal Expansion Valves
- Transducers
- View All
- Cleaning Equipment & Tools
- Cold Room Parts and Accesories
- Commercial Chiller Components
- Component
- Compressor
- Compressor Accessories
- Condensate Drainage Pump
- Condensing Unit
- Cooling Coil
- Cooling Tower Spare Part
- Copper and Fittings
- Copper Piping Leak Test
- Coupling
- Daikin /Acson / York Spare Parts
- Electrical
- Electronic Air Cleaner
- FAN BLADE / FAN PROPELLER
- Fan Coils
- Fan Motor
- Fan Set
- Filter Aircond
- Fire Duct Systems
- FRIDGE & REFRIGERATOR PARTS
- Hardware Items and Tools
- Induction Units
- Innerco Piercing Valve
- Insulation
- Lubricant Oil and Equipment
- Measuring Instrument
- Packaged Indoor
- Panasonic Compressor
- PCB Board
- Pressure Test Equipment and Accessories
- Refrigerant
- Sensors
- Silicone Sealant
- Spray Pump
- Temperature / Humidity Display & Controller
- Underfloor Air Distribution
- Unit Ventilators
- Vacuum Pump
- Valve (Water/Steam Application)
- Water Cooled Chiller
- York Chiller Parts
- Others
- Others
United Faith Sdn Bhd (HQ)
6 (Ground Floor), Jalan BPU 6, Bandar Puchong Utama, 47100 Puchong, Selangor, Malaysia.
+6012-2631315
+6012-5992610
+6012-5992610
SG Branch :
United Faith Pte Ltd
7030, Ang Mo Kio Ave 5, #01-23, Northstar@AMK, Singapore 569880.
+65-9106 6813
KL Branch :
8G, Jalan Pandan 2/3, Pandan Jaya, 55100 Kuala Lumpur, Malaysia.
+6012-491 2610
PJ Branch :
13, Jalan 21/37, SS 2, 47300 Petaling Jaya, Selangor, Malaysia.
+6012-599 2610
Wireless Standard Sensor WS2-T-C-902
Previous | 1 / 6 | Next |
- Carrier Wireless Sensor Malaysia
- Air Conditioner Wireless Sensor Malaysia
- Air-Cond Wireless Sensor Malaysia
As part of Carrier’s wireless sensing line, wireless standard sensors are used to measure temperature & humidity in a space. Because there are no wires to run, they can be added to your building easily.
Wireless sensors work in conjunction with a wireless adapter, which enables wireless communication between the sensors and an i-Vu® BACnet controller in the space. By sensing temperature, humidity and occupancy wirelessly, our i-Vu controllers can make smart decisions to optimize the control of heating, cooling, and lighting systems in the building, providing optimum occupant comfort and energy efficiency.
- Easy to install
- Communicates on the Rnet sensor network via a wireless adapter
- Can be installed up to 80’ away from wireless adapter
- Enables wireless sensing on new or retrofit projects
- Wireless software included for quick and easy sensor pairing
-
Available sensing options include:
- Temperature only (WS2-T-C-902)
- Temperature and humidity (WS2-TH-C-902)
- Temperature through remote sensor (WS2-R-C-902). Remote sensor is sold separately.
- Wireless and battery-less space sensors (assuming sufficient lighting exists in space)
- Maintenance-free capacitors power the sensors during unlit periods for up to 5 days without a light source
- No repeaters or amplifiers required for zone-based applications
- Can co-exist on Rnet with Carrier’s wired ZS sensors
- Single-zone controllers can support a total of 5 sensors
- Multi-zone controllers can support up to 15 sensors
Power supply | Solar harvesting, internal energy storage |
Supplemental battery | A 1/2 AA 3.6 V 1200 mA battery is included to supplement power during commissioning and for low-light conditions |
Maximum operating life | Up to 5 days with no light power or battery |
Time to fully charge | Depends on available lux. Full charge in 8 hours @ 1000 lux or 24 hours @333 lux |
Temperature sensor measuring range | 32° to 104°F (0° to 40°C) |
Remote temperature sensor input | 10k Thermistor Type II (Purchased separately) |
Humidity sensor | 11% to 89%, ±3% RH typical |
Motion sensor | Panasonic AMN42122 - Effective detection range: 16.4 ft. (5 m) maximum |
Protocol | Customized version of EnOcean® |
Radio frequency | 902 MHz (North America) |
Transmission range | Typically, 75-80ft. (18.29 m) maximum from wireless adapter, assuming sensor and wireless adapter are separated by no more than 1 drop ceiling or 2 walls (drywall with metal studs |
Transmission interval |
Configurable in SensorBuilder. The sensor transmits: • On change of sensed value, and • At a regular interval (heartbeat). The default is every 15 minutes |
Change of value threshold | Configurable in SensorBuilder. The temperature must change by at least .288°F (.156°C) (the default) for the sensor to send a change of value |
Minimum illumination strength | 150 lux, constant |
Degree of protection | IP50 |
Operating environment | 32° to 122°F (0° to 50°C) 5% to 95% relative humidity (non-condensing) |
Housing | ABS plastic, traffic white color |
Weight | 0.20 lb. (.08 kg) |
Dimensions | 3.555 in. W x 3.768 in. H x 0.840 in. D (9.030 cm W x 9.570 cm H x 2.134 cm D) |
Compliance |
United States of America FCC CFR 47, Chapter 1, Subchapter A, Part 15, Subpart B Class B Contains FCC ID: SZV-STM300U UL-916 (PAZX) Energy Management Equipment Canada Industry Canada Compliant, ICES-003, Class B cUL Listed UL-916, PAZX7, Energy Management Equipment Europe EN50491-5-2:2009; Part 5-2: EMC requirements for HBES/BACS used in residential, commercial and light industry environment EN50491-3:2009 Part 3: Electrical safety requirements for Home and Building Electronic Systems (HBES) and Building Automation and Control Systems (BACS) Low Voltage Directive: 200695/EC RoHS Compliant: 2011/65/EU Australia and New Zealand C-Tick Mark AS/NZS 61000-6-3 |