- Ducting, Diffuser and Accessories
- Packaged Outdoor
- Split Systems and Condensers
- Actuator
- Air Compressor Parts, Components and Accessories
- Air Cond Bracket
- Air Conditioner Sensor
- Air Conditioning Control System
- Air Cooled Chiller
- Air Cooler
- Air Filters
- Air Handlers
- Air Handling System
- Air Swing Motor
- Air Swing Motor (Small)
- Air Terminals HVAC
- Air-Cond and Refrigeration Tooling
- Air-Conditioner Unit
- Anti Clog
- Automatic Drain Valve
- Belting
- Brazing Equipment & Accessories
- Carrier Parts
- Chemicals
- Chilled and Induction Beams
- Chiller Components
- Chiller Parts
- Actuators
- Bearings and Bushing
- Compressors
- Contactors
- Electronic Components
- Fans and Fan Blower Parts
- Filters and Filter Parts
- Gaskets
- Miscellaneous Electrical Parts
- Miscellaneous Fasteners and Fittings
- Miscellaneous Valves
- Motors
- O - Rings
- Oil and Fluids
- Preventive Maintenance Kits
- Pump
- Relays
- Relief Valves
- Repair Parts Kits
- Solenoid Valves
- Switches
- Thermal Expansion Valves
- Transducers
- View All
- Cleaning Equipment & Tools
- Cold Room Parts and Accesories
- Commercial Chiller Components
- Component
- Compressor
- Compressor Accessories
- Condensate Drainage Pump
- Condensing Unit
- Cooling Coil
- Cooling Tower Spare Part
- Copper and Fittings
- Copper Piping Leak Test
- Coupling
- Daikin /Acson / York Spare Parts
- Electrical
- Electronic Air Cleaner
- FAN BLADE / FAN PROPELLER
- Fan Coils
- Fan Motor
- Fan Set
- Filter Aircond
- Fire Duct Systems
- FRIDGE & REFRIGERATOR PARTS
- Hardware Items and Tools
- Induction Units
- Innerco Piercing Valve
- Insulation
- Lubricant Oil and Equipment
- Measuring Instrument
- Packaged Indoor
- Panasonic Compressor
- PCB Board
- Pressure Test Equipment and Accessories
- Refrigerant
- Sensors
- Silicone Sealant
- Spray Pump
- Temperature / Humidity Display & Controller
- Underfloor Air Distribution
- Unit Ventilators
- Vacuum Pump
- Valve (Water/Steam Application)
- Water Cooled Chiller
- York Chiller Parts
- Others
- Others
United Faith Sdn Bhd (HQ)
6 (Ground Floor), Jalan BPU 6, Bandar Puchong Utama, 47100 Puchong, Selangor, Malaysia.
+6012-5992610
SG Branch :
United Faith Pte Ltd
7030, Ang Mo Kio Ave 5, #01-23, Northstar@AMK, Singapore 569880.
+65-9106 6813
KL Branch :
8G, Jalan Pandan 2/3, Pandan Jaya, 55100 Kuala Lumpur, Malaysia.
+6012-491 2610
PJ Branch :
13, Jalan 21/37, SS 2, 47300 Petaling Jaya, Selangor, Malaysia.
+6012-599 2610
Adjustable Current Switches NSA-ADJ-CURRENT
Previous | 8 / 12 | Next |
- Air Conditioner Sensor Malaysia
- Carrier NSA Series Sensors Malaysia
- Carrier Sensor Accessories Malaysia
- Carrier Non-Communicating Sensors Malaysia
- NSA-A/ACS2 NSA-A/ASCS2 NSA-A/ASCS2-L
Part Numbers
NSA-A/ACS2
NSA-A/ASCS2
NSA-A/ASCS2-L
The Adjustable Current Switches are designed for use in any AC current monitoring application in which you are looking to monitor a particular piece of equipment for equipment failure, preventative maintenance, status, and electrical load status. The current switches should be installed on the line side of the power to the electrical equipment. The current switches are available in both solid and split-core versions which also includes a Patented 35 mm Din Rail mounting foot for easy installation in panel mount applications. The solid-core versions are a great choice for new installations or OEM applications in which cost sensitivity, lower trip points and environmental issues may be of concern.
Applications
Overload Conditions, Underload Conditions, Normal Operating Conditions, Broken Belts, Belt Slippage, Locked Rotors, Equipment Failure, Fans, Pumps, Compressors, Motors, Ovens, Industrial Equipment, Lighting Status and Usage, Electrical Load Status, Local Alarms (Strobes and Audible Alarms), Preventative Maintenance Scheduling
Monitored Current Type: | AC Current |
Maximum Working Voltage: | 600 VAC |
Core Style: | NSA-A/ACS2: Solid | NSA-A/ASCS2: Split | NSA-A/ASCS2-L: Split |
Operating Frequency Range: | 40 to 1 kHz |
Sensor Power: | Induced from the Monitored Conductor |
Amperage Range: | 0 to 250A |
Isolation Voltage: | 2200 VAC |
Trip Point Style | Trip Point: |
Adjustable NSA-A/ACS2: 0.5 to 220A | NSA-A/ASCS2: 1.5 to 220A NSA-A/ASCS2-L: 0.6 to 180A |
Hysteresis: | 10% of trip point, typical |
Contact Type: | Normally Open (N/O) |
“Status” Contact Rating: | 0.2A @ 200 VAC/VDC |
“Status” Contact “On” Resistance | “O” Resistance: | < 10 Ohms (tripped) | > 1 Meg Ohms (Open) |
Response Time: | See Response Time Table |
Status LED Indication: |
Red LED (Current above Trip Point) Blue LED (Current Below Trip Point) |
Aperture Size: | 0.75” (19.05 mm) |
Din Rail Size: | 35 mm (U.S. Patent No. 7,416,421) |
Operating Temperature Range: | 5 to 104ºF (-15 to 40ºC) |
Operating Humidity Range: | 0 to 95%, non-condensing |
Recommended Storage Temperature | RH Range: | 41 to 95°F (5 to 35°C) | 40% to 85% RH, non-condensing |
Enclosure Material | Flammability Rating: | PC/ABS (Polycarbonate/ABS Blend) | UL94-V0 |
Wiring Connections: | 2 Position, Screw Terminal Block (Not Polarity Sensitive) |
Wire Size: | 16 to 22 AWG (1.31 mm2 to 0.33 mm2) Copper Wires only |
Terminal Block Torque Rating: | 4.43 to 5.31 in-lbs. (0.5 to 0.6 Nm) |
Minimum Mounting Distance: | 1” (2.6 cm minimum) between current switch (Relays, Contactors, Transformers) |
Agency Approvals: | UL/CUL US Listed (UL 508) Ind. Control Equipment (File # E309723), CE, RoHS2, WEEE |
Product Weight: |
NSA-A/ACS2: 0.216 lbs. (0.097 kg) | NSA-A/ASCS2: 0.270 lbs. (0.123 kg) NSA-A/ASCS2-L: 0.280 lbs. (0.127 kg) |
Product Dimensions (L x W x H): |
Solid Core: 2.760” (70.11 mm) x 3.343” (84.92 mm) x 1.050” (26.67 mm) Split Core: 2.780” (70.51 mm) x 3.238” (82.25 mm) x 1.120” (28.45 mm) |
Model # | 0.50 Amps | 0.60 Amps | 0.75 Amps | 1.0 Amps | 1.5 Amps | 10 Amps | 20 Amps |
NSA-A/ACS2 | 221 mS | - | 144 mS | 109 mS | - | 63 mS | 59 mS |
NSA-A/ASCS2 | - | - | - | - | 248 mS | 68 mS | 65 mS |
NSA-A/ASCS2-L | - | 400 mS | 270 mS | 183 mS | - | 62 mS | 60 mS |