United Faith Sdn Bhd (HQ)
6 (Ground Floor), Jalan BPU 6, Bandar Puchong Utama, 47100 Puchong, Selangor, Malaysia.
+6012-2631315
+6012-5992610

SG Branch :
United Faith Pte Ltd

7030, Ang Mo Kio Ave 5, #01-23, Northstar@AMK, Singapore 569880.
+65-9106 6813

KL Branch :
8G, Jalan Pandan 2/3, Pandan Jaya, 55100 Kuala Lumpur, Malaysia.
+6012-491 2610

PJ Branch :
13, Jalan 21/37, SS 2, 47300 Petaling Jaya, Selangor, Malaysia.
+6012-599 2610

WeatherMaker® Standard Efficiency Single-Packaged Rooftop Units 50KCQ Heat Pump Units 3 to 5 Nominal Tons

Previous 11 / 35 Next

WeatherMaker® Standard Efficiency Single-Packaged Rooftop Units 50KCQ Heat Pump Units 3 to 5 Nominal Tons Carrier Commercial Packaged Rooftop Units  Packaged Outdoor


Heat Pump Units

3 to 5 Nominal Tons

WeatherMaker® 50KCQ rooftop units were designed to be easy to install, maintain, and operate, with customer-requested features including a gage port, centralized control center, plug-and-play accessory board, ''no-strip screw'' collars, and handled access panels. Units are field-convertible to horizontal airflow without special adapter curbs or kits, making it easy for the installer to adjust to unexpected jobsite complications. Units are pre-wired and pre-charged with Puron (R-410A) refrigerant and are factory tested.


carrier-AHRI-210-240-Unitary-Small-AC

Performance Features

  • ASHRAE 90.1 compliant
  • Single-stage cooling capacity control
  • Up to 14.3 SEER, 12.2 EER and 8.2 HSPF
  • Cooling operating range up to 115 °F (46°C) and down to 25°F (-4°C) using winter start kit
  • Innovative non-corrosive composite condensate pan in accordance with ASHRAE 62 Standard, sloping design; side or center drain
  • Pre-painted exterior panels and primer-coated interior panels tested to 500 hours salt spray protection

Maintenance Features

  • Control terminal board facilitating simple safety circuit troubleshooting and simplified control box arrangement
  • Access panels with easy grip handles
  • Innovative, easy starting, no-strip screw feature on unit access panels
  • Direct Drive – ECM indoor fan motor standard with optional belt drive systems available
  • Two-inch disposable return air filters

Installation Features

  • Same footprint as installed Carrier 3-5 ton rooftops back to 1989, reducing installation costs and time
  • Field convertible from vertical to horizontal airflow configuration
  • Provisions for thru-the-bottom power entry capability as standard
  • Single point gas, electric, and controls connections
  • Full perimeter base rail with built-in rigging adapters and fork truck slots

Reliability Features

  • Scroll compressors with internal line-break overload protection
  • Compressor crankcase heaters (sizes 05 to 06 sizes)
  • 24-volt control circuit protected with resettable circuit breaker
  • Permanently lubricated evaporator-fan motor
  • Totally enclosed condenser motors with permanently lubricated bearings
  • Low pressure and high-pressure switch protection
  • Liquid line filter drier as standard
 
Factory-Installed Field-Installed
Cabinet
Thru the base electrical or gas line connections X X
Hinged access panels X  
Coil Options
Cu/Cu indoor and/or outdoor coils X  
Pre-coated outdoor coils X  
Premium, e-coated outdoor coils X  
Condenser Protection
Condenser coil hail guard (louvered design) X X
Controls
Thermostats, temperature sensors and subbases   X
PremierLink DDC communicating controller X X
RTU Open multi-protocol controller X X
Smoke detector (supply and/or return air) X  
Time Guard II compressor delay control circuit   X
Filter status switch   X
Fan status switch   X
Economizers & Outdoor Air Dampers
EconoMi$er IV (for electro-mechanical controlled RTUs) X X
EconoMi$er X (for electro-mechanical controlled RTUs with CA Title 24 FDD) X X
EconoMi$er 2 (for DDC controlled RTUs) X X
Ultra-low leak economizer dampers X X
Motorized 2-position outdoor air damper X X
Manual outdoor dir damper   X
Barometric relief X X
Power exhaust   X
Economizer Sensors & IAQ Devices
Single dry bulb temperature sensors X X
Differential dry bulb temperature sensors   X
Single enthalpy sensors X X
Differential enthalpy sensors   X
CO2 sensor (wall, duct, or unit mounted) X X
Electric Heat
Multiple electric resistance heater kW sizes   X
Single point kit   X
Indoor Motor & Drive
Multiple motor and drive packages X  
Low Ambient Control
Winter start kit   X
Motormaster head pressure controller   X
Power Options
Convenience outlet (powered) X  
Convenience outlet (unpowered) X  
Non-fused disconnect X  
Roof Curbs
Roof curb 14'' (356mm)   X
Roof curb 24'' (610mm)   X
Nominal Cooling Ton Size Cooling Stages AHRI Efficiency (SEER) EER Dimensions (in) LxWxH At 47°F At 17°F Unit Weight (lb)
Heating Capacity (Btuh) HSPF Heating Capacity (Btuh) COP
3 1 (14.0) 74x47x33 35600 (8.1) 18400 N/A 495
4 1 (14.0) 74x47x33 45500 (8.0) 23800 N/A 580
5 1 (14.1) 74x47x41 58000 (8.2) 28600 N/A 610

Please leave your enquiry here, we will reply as soon as possible.
Name*  
Company Name  
Product Interested  
Quantity  
Email*  
Contact No.*  
Attachment  
*only support gif, jpeg, jpg, png, pdf
Messages*  

Switch to Mobile Version